Ventilation, function - GF83.10-P-2000I

MODEL 220 

Ventilation function without rear air conditioning 

Fig 1: Air Ventilation Function Diagram Without Rear Air Conditioning
G04851312

Ventilation function with rear air conditioning 

Fig 2: Air Ventilation Function Diagram With Rear Air Conditioning
G04851313

Function 

The ventilation

In normal operation, with the vehicle standing still or to increase the air quantity, ventilation is achieved with the support of the blower for the air conditioning (automatic) and blower for the rear air conditioning (with code 582).

Fresh air is sucked in through the air intake in the engine hood and through the fresh air flap in the A/C housing. The air passes through the air ducts to the air outlets into the passenger compartment depending on the settings on the pushbutton control module. In the recirculated air mode the blower sucks air out of the vehicle passenger compartment and conveys it in the recirculated air flap through the A/C housing.

The rear air conditioning operates exclusively with air from the vehicle passenger compartment.

The air passes through ventilation slits below the rear shelf into the trunk and from there passes out of the vehicle through the rear vents.

  Air inlet, location/function   GF83.10-P-2138I 
  Air ducts, location/purpose   GF83.10-P-2139I 
  Blower, location/purpose/design/function   GF83.10-P-2140I 
    with code 582 (rear air conditioning) GF83.10-P-2140M 
  Blower regulator, location/purpose/function   GF83.10-P-2141I 
    with code 582 (rear air conditioning) GF83.10-P-2141M 
  Dust filter, location/purpose/function   GF83.10-P-2142I 
  Rear ventilation, location/purpose/function   GF83.10-P-2143I 
  Defroster nozzle, location/purpose/function   GF83.10-P-2144I 
  Center nozzle, location/purpose/design/ function   GF83.10-P-2107I 
  Side nozzle, location/purpose/design/function   GF83.10-P-2108I 
  Front footwell air outlet, location/purpose/ function   GF83.10-P-2145I 
  Rear footwell air outlet, location/purpose/ function   GF83.10-P-2146I 
  Rear nozzle, location/purpose/design/function   GF83.10-P-2111I 
  Stowage compartment ventilation nozzle, location/purpose/function   GF83.10-P-2147I 
  Defroster nozzle flap actuator motor, location/ purpose/function   GF83.10-P-2129I 
  Diverter flap actuator motor, location/purpose/ function   GF83.10-P-2130I 
  Blend flap actuator motor, location/purpose/ function   GF83.10-P-2131I 
  Footwell flap actuator motor, location/purpose/ function   GF83.10-P-2132I 
  Door vent, location/purpose/function   GF83.10-P-2133I 
  Rear compartment side vent, location/purpose/ function   GF83.10-P-2134I 
  Multifunction sensor, location/purpose/function   GF83.10-P-2148I 
  Fresh air/recirculated air flap, location/ purpose/design/function   GF83.20-P-2104I 
  Air distribution switch, location/purpose/ function   GF83.25-P-2103I 
  Fresh air/recirculated air flap actuator motor, location/purpose/function   GF83.30-P-2116I 
  Activated charcoal filter actuator motor, location/purpose/function   GF83.30-P-2117I 
  Activated charcoal filter, location/purpose/ function   GF83.30-P-2118I 
  Blower button, location/purpose/function   GF83.40-P-2144I 
  Recirculated air button, location/purpose/ function   GF83.40-P-2145I 
  Automatic air conditioning housing, location/ purpose/design/function   GF83.40-P-2105I 
  Auto button, location/purpose/function   GF83.40-P-2147I 
  Activated charcoal filter button, location/ purpose/function   GF83.40-P-2149I 
  Defroster button, location/purpose/function   GF83.40-P-2139I 
  Center nozzle electronics control module, location/purpose   GF83.40-P-2157I 
  Electronic stepping motor control module, location/purpose   GF83.40-P-2158I 
  Rear air conditioning air distribution flap actuator, location/purpose/function with code 582 (rear air conditioning)   GF83.50-P-2100M 
  Rear air conditioning air distribution controller, location/purpose/function with code 582 (rear air conditioning) GF83.50-P-2101M 
  Rear air conditioning housing, location/ purpose/design/function with code 582 (rear air conditioning) GF83.50-P-2117M 
  Rear air conditioning blower button, location/ purpose/function with code 582 (rear air conditioning) GF83.50-P-2105M