Home >> Mercedes Benz >> 2001 >> S500 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control -- Basic Knowledge -- 215 & 220 Chassis >> Basic Knowledge >> Stepping motor electronic control module, location/purpose - GF83.40-P-2143 >> Stepping motor electronic control module, purpose - GF83.40-P-2143-02I

Stepping motor electronic control module, purpose - GF83.40-P-2143-02I

Purpose 

The 10 actuator motors on the A/C housing are controlled by the stepping motor electronic control module. The switching logic is realized by the automatic A/C pushbutton control module.

The flap settings are adjusted infinitely from 0 % (closed) to 100% (open) by the stepping motor electronic control module according to the position settings received from the automatic A/C pushbutton control module via the A/C bus.

The electronic flap control completes all adjustments with a resolution of 1 %. It is necessary to realize the following LOOSE function for each flap in the automatic A/C pushbutton control module so that the actuator motors do not run continuously within the control range.

LOOSE-function: Once a position is reached, it is necessary for the air outlet temperature at the center vent to change to such an extent that the next higher or lower LOOSE value is exceeded or left below before the position is changed again

End values (0%; 100%) are moved to directly.

LOOSE function "A" automatic flap program "B" manual flap program Center vent in manual mode
Left/right defroster flaps 10% Fixed values (see table below) Control according to "A" or "B"
Left/right footwell flaps 5% Fixed values (see table below) Control according to "A" or "B"
Left/right blend flaps 10% 10% 1%
Left/right diverter flaps 10% 10% 1%
Fresh/recirculated air flap Fixed values 0%, 80%, and 100% Fixed values 0%, 80%, and 100% Fixed values 0%, 80%, and 100%
Activated charcoal filter Fixed values 0% and 100% Fixed values 0% and 100% Fixed values 0% and 100%

Ignition off 

The actuation motors move to the following positions one minute after switching off the ignition:

Ignition on 

The following positions apply for the first 30 seconds after switching on the ignition:

Exceptions 

Mode change to automatic flap operation 

Generally there is a so-called mode change-over range for all flaps at the transition from the heating mode to the A/C-mode and vice versa.

Setting deviation < -4 °C 

Setting deviation > -4 °C 

Left/right setting Left defroster nozzle Left footwell nozzle Right defroster nozzle Right footwell nozzle Left blend flap Right blend flap Left diverter flap Right diverter flap Fresh air/recirculated air flap
Hi/- 60% 0% without FRA 100% with FRA - - 0% - 0% - 0%
-/Hi - - 60% 0% without FRA 100% with FRA - 0% - 0% 0%
LO/- 0% 50% - - 100%(1) - 100%(1) - 0%
- /LO - - 0% 50% - 100%(1) - 100%(1) 0%
LO/LO and AUTO/AUTO 0% 50% 0% 50% 100%(1) 100%(1) 100%(1) 100%(1) 100% (not with EC mode)
(1) Means multiplication by the associated potentiometer value for the air quantity dial in the center vent.
NOTE:
  • Manual air distribution (also recirculated air switchover), fixed programs have priority over the flap positions specified above.
  • In the same manner a manual setting on the center vent has priority over the blend and diverter flap values in the table above