Blower regulator, function - GF83.10-P-2103-01I
Function
With the blower buttons (
) or in the automatic mode a control voltage (0 - 6 V) is transferred from the automatic A/C pushbutton control module to the blower regulator. The latter then regulates the operating voltage (0 - 12 V) according to the control voltage. This provides the control of the blower speed in the range of 0 - 100 %.
| Blower switch position (reading on display) | Blower control voltage (manual) | Blower control voltage (automatic mode) |
|---|---|---|
| 1 segment | min. 1.60 V | 0 V to 1.70 V |
| 2 segment | 1.80 V | 1.70 V to 1.90 V |
| 3 segment | 2.00 V | 1.90 V to 2.15 V |
| 4 segment | 2.30 V | 2.15 V to 2.60 V |
| 5 segment | 2.85 V | 2.60 V to 3.10 V |
| 6 segment | 3.60 V | 3.10 V to 4.55 V |
| 7 segment | max. 6.00 V | 4.55 V to 6.00 V |