Receiving remote control signal, function - GF80.20-P-4011S

MODEL 215, 220 

The radio frequency remote control signal is received via the rear window antenna. The receiver in the top rear window antenna amplifier (A2/12)  converts the radio signal into a data signal. The overhead control panel control module (N70)  receives this data signal via a data bus.

The infrared signal is received by the left front door IR receiver (A26/1)  or by the right front door IR receiver (A26/2)  .

The control module connected to the corresponding receiver evaluates the signal.

The code for access authorization and the remote control command in the signal are transferred to the electronic ignition/starter switch control module (N73)  as a CAN message. The electronic ignition/starter switch control module (N73)  checks the code for access authorization and sends the corresponding command to the CAN bus if the code is correct.

  Antenna amplifier module, location/purpose/design/function   GF82.62-P-3105
  Infrared receiver, location/purpose/design/function   GF80.20-P-4101S 
  Electronic ignition switch (EIS) control module, location/purpose/design/function   GF80.57-P-4102S 