LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2001 >> S500 >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Accessories Control Systems >> Battery, Fuse/Relay Box, Modules, Sensors & Switches -- Testing & Repair -- 215 & 220 Chassis >> Testing & Repair >> Treatment of battery if vehicle taken out of service - AR54.10-P-0006I

Treatment of battery if vehicle taken out of service - AR54.10-P-0006I

MODEL 215, 220 

DANGER Risk of explosion  caused by oxyhydrogen gas. Risk of poisoning and caustic burns  caused by swallowing battery acid. Risk of injury  caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fire, sparks, open flames or smoking.
Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers.
AS54.10-Z-0001-01A
1 Check battery, charge battery if necessary   AR54.10-P-1129I 
2.1 Disconnect battery ground cable IMPORTANT When the vehicle is laid up for more than 4 weeks. This prevents the battery being discharged by closed-circuit accessories. AR54.10-P-0003I 
3 Charge battery IMPORTANT When battery is disconnected every 6 months at the latest and when the battery is connected every 6 weeks at the latest. AR54.10-P-1130I