Deployment of removed airbag units - AR91.60-P-0611-02A
Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect the power supply.
Models 124, 129 up to 30.6.93, 140, 202 up to 30.6.93
Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect power supply and unplug the SRS test connector (X11/13).
Models 163, 168, 170, 202, 203, 208, 209, 210, 215, 220, 230, 240, 414, 461, 463
All models
- Plug the 2-pin plug connector (8) into the unit to be scrapped.
- Dial the rotary switch (4) to position "1".
- Press the battery control pressure switch (2) and deployment pressure switch (3) simultaneously.
- For airbag units with 2 squibs, both must be deployed. To do this, repeat steps 1 through 3 after plugging the ignition cable into the second squib.
Keep a distance of 10 meters for safety.
After a successful deployment, the deployment indicator light (5) flashes.
Using the deployment device