ME-SFI fuel pump - Testing hydraulic system - AD07.61-P-7001A
ENGINES 112.910,
112.911 up to 31.5.00,
112.920,
112.921 up to 31.5.00,
112.923,
112.940 /941 /942 up to 31.5.00,
112.943
| Hazard from contact with parts conducting high voltages. | Do not touch parts which conduct high voltages. Persons who wear electronic implants (e.g. heart pacemakers) must not carry out work on the ignition system. | AS15.10-Z-0001-01A | |
| Lethal hazard from being drawn into rotating vehicle parts | Do not reach into rotating parts. Wear closed and close-fitting work clothes. Secure area of rotating vehicle components against unauthorized access. |
AS00.00-Z-0004-01A | |
| Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel. | No fire, sparks, naked flames or smoking. Pour fuels only into suitable and appropriately marked containers. Wear protective clothing when handling fuel. |
AS47.00-Z-0001-01A | |
| When disconnecting the connectors on the ME-SFI control module, disconnect the middle connector first and when connecting, connect the middle connector D last. | |||
| Connection and use of testing equipment | AD00.00-P-1000AZ | ||
| Gasoline injection and ignition system (ME-SFI) - diagnosis - previous knowledge | AD07.61-P-2000A | ||
| Connect socket box at ME-SFI control module (N3/10) | |||
| Checking | |||
| 1 | Fuel pump - Testing hydraulic system, ME-SFI fuel pump | Delivery rate | AD07.61-P-7001-01A |
| 2 | Fuel pump - Testing hydraulic system, ME-SFI fuel pump | Power consumption | AD07.61-P-7001-01B |