ME-SFI 1-2/4-5 shifting solenoid valve - Fault code description - AD07.61-P-4000-38A
| 1 | Fault code | P0753 |
| 2 | Fault storage | Following the expiry of the test duration and fault |
| Activation of the engine diagnosis (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp |
Following two consecutive driving cycles with fault | |
| 3 | Frequency of the test | Continuously |
| 4 | Checked signal or status | Voltage supply |
| 5 | Fault setting conditions | < 0.4 V |
| Short-circuit to ground | Approx. 8.5 V | |
| Lower limit value, voltage | Approx. 15 V | |
| Upper limit value, voltage | Approx. 0.300 A | |
| Lower limit value, current | Approx. 0.700 A | |
| Upper limit value, current | Approx. 1 s | |
| Duration of test | ||
| 6 | Faults (lead interruption or short-circuit of control, short-circuit in the valve) are detected by the ETC control module; the ME-SFI control module is then informed of these via the CAN data bus. Fault storage and the activation of the malfunction indicator lamp are carried out by the ME-SFI control module. Additionally read out ETC diagnostic trouble code memory, fault code 2. |