1 Fault code P0446
2 Fault storage after the end of the test period and faults
Activation after two successive driving cycles with faults
"CHECK ENGINE" malfunction indicator lamp (MIL) USA ONLY  
3 Frequency of the test continuous
4 Checked signal or status Voltage and current for activated charcoal canister shutoff valve
5 Fault setting conditions  Voltage < 4 V
Limits Current > 4.2 A
  Short circuit to ground no voltage at the activated charcoal canister shutoff valve
Short circuit to +12 V approx. 4 - 8 V at unloaded output of ME-SFI control module
Line interruption approx. 1 s
Test duration    
6 IMPORTANT The activation of the activated charcoal canister shutoff valve is tested for line interruption and short circuit (to ground or battery voltage). Short circuit to ground and line interruption is determined with a blocked output stage, whereas short circuit to battery voltage is determined with a conducting output stage.
In the event of faults, the output stage is immediately no longer activated.