Fault code description - ME-SFI - knock sensor - AD07.61-P-4000-12A
| 1 | Fault code | P0325 right P0330 left |
| 2 | Fault storage | Fault is stored immediately |
| Activation of malfunction indicator lamp for engine diagnosis (EURO3/4) or CHECK ENGINE (MIL) |
Malfunction indicator lamp is not activated | |
| 3 | Frequency of the test | continuous |
| 4 | Checked signal or status | Knock sensor signal (comparison value calculated in the ME-SFI control module) |
| 5 | Fault setting conditions | approx. 0.10 V |
| Lower limit Upper limit |
approx. 4.98 V | |
| 6 | Test prerequisites |
|
| 7 | In the case of faults, safety retarding of ignition timing is implemented at all cylinders |