Test of electrical system CF front left power window relay - AD72.29-P-6000-20GH
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Left front power window relay (F1k18) Function | Replace relay F1 k18 by relay of the same design, e.g. right front power window relay (F1k16) Press switch S21s1 into 2nd detent position: | Window opens completely | Value in order: