LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2001 >> ML430 >> Repair and Diagnosis >> Body & Frame >> Ignition Switch/Steering Lock >> Anti-Theft & Central Locking System -- 163 Chassis >> Basic Knowledge >> Tripping of anti-theft alarm (ATA), function - GF80.50-P-2004GH

Tripping of anti-theft alarm (ATA), function - GF80.50-P-2004GH

MODEL 163 with CODE (551a) Anti-theft alarm (ATA) 

The anti-theft alarm (ATA)  can be triggered by

This assumes that the inputs in question are armed by activation of the ATA  .

The armed inputs are checked by the all-activity module (AAM) (N10)  . If the same input is not in the non-actuated state during two checks in sequence, the AAM triggers the acoustic  as well as visual alarm  .

IMPORTANT An alarm can be triggered from one input a maximum of three times in sequence.

Moreover the alarm can be triggered with the panic switch  on the remote control key  .

IMPORTANT The operating sequence for the acoustic panic alarm differs from that of the ATA alarm!

  Activating anti-theft alarm (ATA), function   GF80.50-P-2002GH 
  Triggering alarm by contact with exterior surface   GF80.50-P-3015GH 
  Interior protection system, function   GF80.50-P-2006GH 
  Anti-towing sensor (ATS), function   GF80.50-P-2007GH 
  Triggering alarm with panic switch   GF80.50-P-3014GH 
  Acoustic alarm, function   GF80.50-P-4005GH 
  Visual alarm, function   GF80.50-P-4006GH 
  All-activity module (AAM)   GF54.21-P-4100GH