Initial filling of battery - AR54.10-P-0001Z
MODELS all
Maximum fluid level
| Filling | |||
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury from caustic burns to eyes and skin from battery electrolyte or from handling damaged lead acid batteries. | No fire, sparks, naked flames or smoking. Wear acid-protective gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Pour in battery electrolyte up to inner level marking with a filling device | Let the battery stand for approximately 20 minutes and afterwards control the fluid level if necessary. | |
| *WE58.40-Z-1001-22A | |||
| Notes on battery | All models | AH54.10-P-0001-01A |
Workshop equipment
| WE58.40-Z-1001-22A | Tank emptying device |