Initial filling of battery - AR54.10-P-0001Z

MODELS all 

Maximum fluid level 

Fig 1: Identifying Battery Maximum Fluid Level
G04607762
  Filling    
DANGER Risk of explosion  from explosive gas. Risk of poisoning and caustic burns  from swallowing battery electrolyte. Risk of injury  from caustic burns to eyes and skin from battery electrolyte or from handling damaged lead acid batteries. No fire, sparks, naked flames or smoking. Wear acid-protective gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers. AS54.10-Z-0001-01A 
1 Pour in battery electrolyte up to inner level marking with a filling device Let the battery stand for approximately 20 minutes and afterwards control the fluid level if necessary.  
    COMMERCIALLY AVAILABLE TOOLS *WE58.40-Z-1001-22A 
NOTES Notes on battery All models AH54.10-P-0001-01A 
Workshop equipment

WE58.40-Z-1001-22A Tank emptying device