Adaptive damping system (ADS II) test of hydraulic system pressurized oil pump delivery - AD32.32-P-7000-01B
| Scope of test | Measuring instrument/Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Pressure oil pump Delivery rate |
250 bar at level controller connection S2 |
Engine: Idling Level controller lever in position "F" = Fill Observe pointer of pressure gauge until pressure does not rise anymore |
>120 bar delivery rate > 0.2 l/min at idle speed | Pressure: < 120 bar Delivery rate < 0.2 l/min
|