Adaptive damping system (ADS II) test of hydraulic system level controller outflow valve - AD32.32-P-7006-03A
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Function of outflow valve | 250 bar at level controller connection S2 |
Engine: Idling Level controller lever in position "F" = Fill until approx. 80 bar is reached. Level controller lever in position "L" = Empty |
30-36 bar |
|