Connect compression tester - AR01.10-P-0010-01PR
- Open cover (1) of front backup fuse box (F32).
- Connect clamp (3)
on compression recorder on terminal (2) of front backup fuse box (F32).
Shown on model 203
- Remove cover on fuse box.
Installation: Check the rubber seal in the cover. Replace it if necessary. The cover must be seated in the groove at the rear.
- Remove starter relay (N10/1kS) from relay position S.
- Insert adapter line (6) into relay position S.
- Link adapter cable (6) to the cable of the compression recorder
(7).