Retrofit Linguatronic voice control system wiring harness - AN82.70-P-0004-01PA
Connection schematic for wiring harness
- Unravel voice control system wiring harness (1) up to yellow mark (arrow).
- Connect cable lacing with green, 2-pin coupling from yellow mark (arrow) to black, 15-pin coupling with insulating tape (10) to voice control system wiring harness (1).
Install blue/black (bl/sw) lead from the yellow marking (arrow) in the frame floor system, right wiring duct.
- Route voice control system wiring harness (1) with black, 15-pin coupling, brown ground cable lacing, green 2-pin coupling and the two black, 2-pin couplings with yellow mark from start of right rear cable duct (arrow) along existing leads on wheelhouse and fasten.
- Route voice control system wiring harness (1) into trunk through opening.
- Route voice control system wiring harness (1) with brown ground cable lacing and the two black, 2-pin couplings along existing leads and fasten.
- Connect brown wire (br) to ground (right wheel housing in trunk) (W7).
- Attach the two black 2-pin couplings of the voice control system wiring system (1) to the microphone separation point standard coupling (X58/3) and fasten.
- Route blue/black (bl/sw) lead in right wiring duct to black 10-pin wake-up signal connector (X30/8).
The wake-up signal connector (X30/8) is in the right cable duct, just before the right A-pillar.
- Insert blue/black (bl/sw) lead into chamber 5 of existing black, 10-pin wake-up signal connector (X30/8).
- Route voice control system wiring harness (1) with green, 2-pin coupling and black, 15-pin coupling along existing leads in right trunk and on control unit plate and fasten.
- Connect black, 15-pin connector to voice control system control unit (A35/11).
- Route voice control system wiring harness (1) with green, 2-pin coupling to rear SAM control unit with fuse and relay module (N10/2) along present leads and fasten.
- Insert green, 2-pin connector into free plug location (5, arrow) of rear SAM control unit with fuse and relay module (N10/2).
Plug location 5 is marked in green color. Tie back excess.