LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2001 >> C240 Standard >> Repair and Diagnosis >> Accessories & Equipment >> Interior/Exterior Trim >> Doors & Windows -- 203 Chassis >> Basic Knowledge >> Automatic raising/lowering power windows, function - GF72.29-P-3007PP

Automatic raising/lowering power windows, function - GF72.29-P-3007PP

MODEL 203 

Function requirements: 

IMPORTANT Model 203.7 is not equipped with rear door control modules and power window motors.

Operation 

The automatic raising/lowering function is performed by briefly pulling back or pushing forward a power window switch in the "close" or "open" direction beyond the first click-stop position.

Via corresponding:

the corresponding:

are actuated.

The actuation remains active until it recognizes via position recognition that the window is completely closed or opened.

Automatic raising 

The "automatic raising" function effects automatic window raising with excess force limitation (pinch protection) and can only be performed on synchronized windows. As long as no other button signals are detected, the window will be completely closed to the upper end stop position.

If the system detects that the rotation direction of the power window motor is incorrect or that a Hall sensor is defective for 12 rotations of the armature, automatic raising is immediately aborted.

Upon detecting an "incorrect rotation direction" or "defective Hall sensor" fault, or a desynchronized window, the system will respond to any continued request for "automatic raising" by actuating the "manual raising" function.

If the system recognizes the "manual raising" button function after having recognized the "automatic raising" button function and without first having detected the neutral position, the "automatic raising" function remains active.

Function abort 

The "automatic raising" function is interrupted if:

Automatic lowering 

The "automatic lowering" button function effects automatic window lowering and can be performed without synchronization. As long as no other button signals are detected, the window will be fully lowered to the lower end stop position.

Function abort 

The "automatic lowering" function is aborted if:

  Child protection, function Model 203.0/203.2 GF72.29-P-3008PP