Timeout error of overhead control panel stored in other control units - AF77.20-P-6009A
MODEL 203, 209
OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES
| Category | Op. no. | Operation text |
|---|---|---|
| P | 541011 | Perform quick test |
| P | 825596 | Replace overhead control panel control unit |
| P | 540992 | Code control unit: .................... (after quick test) |
| Damage code | Cause | Remedy | |
|---|---|---|---|
| 82 302 90 | Problems in CAN data bus. | 1 Remove, install and replace overhead control panel. | |
| Timeout error of overhead control panel stored in other control units |
PARTS ORDERING NOTES
| Part no. | Designation | Quantity |
|---|---|---|
| A 203 820 36 01 | Overhead control panel, as of software status Q4 in order | 1 |
| A 203 820 37 01 | Overhead control panel, as of software status Q4 in order | 1 |
| A 203 820 46 01 | Overhead control panel, as of software status Q4 in order | 1 |
| A 203 820 47 01 | Overhead control panel, as of software status Q4 in order | 1 |
| A 203 820 48 01 | Overhead control panel, as of software status Q4 in order | 1 |
| A 203 820 49 01 | Overhead control panel, as of software status Q4 in order | 1 |
| A 209 820 01 01 | Overhead control panel, as of software status Q7 in order | 1 |
| A 209 820 02 01 | Overhead control panel, as of software status Q7 in order | 1 |
| A 209 820 03 01 | Overhead control panel, as of software status Q7 in order | 1 |
| A 209 820 05 01 | Overhead control panel, as of software status Q8 in order | 1 |
| A 209 820 07 01 | Overhead control panel, as of software status Q8 in order | 1 |
| A 209 820 08 01 | Overhead control panel, as of software status Q7 in order | 1 |
| A 209 820 10 01 | Overhead control panel, as of software status Q7 in order | 1 |
| A 209 820 12 01 | Overhead control panel, as of software status Q7 in order | 1 |
| A 209 820 13 01 | Overhead control panel, as of software status Q3 in order | 1 |
| A 209 820 14 01 | Overhead control panel, as of software status Q3 in order | 1 |