Recirculating air flap actuator position/task/design/function - GF09.50-P-3101GS: Notes
ENGINE 111.955 /956 /957 /958 /981 /982 /983
Shown on engine 111.955 Model 203
| Recirculated air flap actuator position | Engine 111.952/56/57/58/82/83 | GF09.50-P-3101-01A | |
| Model 203 with engine 111.955 | GF09.50-P-3101-01B | ||
| Recirculated air flap actuator task | Operating the recirculated air flap steplessly between 0 - 90° for controlling the charge pressure | ||
| Recirculated air flap actuator function | The recirculated air flap actuator is operated by the engine control module. The recirculated air flap actual value potentiometers advise the position of the recirculated air flap to the ME-SFI control module in order to detect the various load states. The flap is always closed (maximum charge pressure) at full load. |