Recirculating air flap actuator position/task/design/function - GF09.50-P-3101G
ENGINE 111.943 /944 /973 /975
| Position | At top part of air cleaner | ||
| Task | Operating recirculated air flap steplessly between 0 - 90° for boost pressure control | ||
| Design/function | The recirculating air flap actuator is operated by means of a PWM signal supplied by the engine control module.
|