Checking charge time of motor-and-pump assembly - AR42.50-P-0001-06MB
The ignition must be switched off.
- Release pressure from booster circuit (depress brake pedal approximately 30 times).
- Switch on the ignition and monitor the period that elapses until the motor-and-pump assembly is deactivated.
Time between 40 and 70 s: System OK.
Time > 70 s: Motor-and-pump assembly defective.
Time < 40 s: Brake booster hydraulic unit is defective.
- Switch off ignition.