LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2000 >> S430 >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Entertainment, Lighting & Wiper/Washer -- Trouble Diagnosis -- 215 & 220 Chassis >> Trouble Diagnosis >> Fault message in instrument cluster (IC) "Check left low beam bulb" - AF82.10-P-8002A

Fault message in instrument cluster (IC) "Check left low beam bulb" - AF82.10-P-8002A

MODEL 220, 215 with xenon headlamp or bi-xenon headlamp 

OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES

Category Op. no. Operation text Time Acc. no. Code
P 541011 Perform quick test 004 WU - -
P 821201 Replace defective bulb on one lamp of exterior lighting 002 WU - -
Damage code Cause Remedy  
  Warning message in instrument cluster "Check left low beam bulb" 1 Perform short test with STAR DIAGNOSIS.  
  The DTC B1630 is stored in the right SAM control unit.
However, low beam is okay.
IMPORTANT The fault B1630 is stored in the right SAM control unit, however the low beam is okay.  
  In individual cases the xenon burner may not ignite during the first ignition attempt due to tolerances of the ignition voltage. 2 Remove/install/replace the front left xenon burner.
IMPORTANT Use only the part numbers listed below. The new xenon burners are from Messrs Philips.
IMPORTANT In the case of complaints do not use Osram xenon burners for models 215 and 220. The optimized xenon burners were added as replacement parts with index 07.
IMPORTANT The ignition voltage tolerances of the xenon burner were optimized.
New xenon burners:
Model 220 before model refinement (before VIN end number 316 717)
N 910 139 000 000 07
Model 220 as of model refinement (clear glass headlamps)
N 910 139 000 001 07
Model 215
N 910 139 000 001 07
 
    3 Erase fault memory.  
PARTS ORDERING NOTES

Part no. Designation Quantity
N 910 139 000 000 07 Xenon burner D2R (Messrs Philips for headlamps with reflection system) As required
N 910 139 000 001 07 Xenon burner D2S (Messrs Philips for headlamps with projection system) As required