Easy-entry seat will not operate - AF91.12-P-6003A
MODEL 163.154 /172 #A as of 145273, 163.136 /154 /172 #X as of 708319, 163.113 /128 /175 with CODE (847) 3rd seat row
Operation no. of operation texts or standard texts and flat rates
| Sector | Op. no. | Operation text | Time | Acc. no. | Code |
|---|---|---|---|---|---|
| P | 023612 | SECURE BOWDEN CABLE FOR EASY-ENTRY RELEASE HANDLE | 005 AW/0,4 h | 92 139 38 | - |
| Damage code | Cause | Remedy | |
|---|---|---|---|
| Release cable disconnected from eyelets at top of telescoping strut. | 1 Slide one piece of shrink-on tubing (1), approximately 25 mm long, onto release cable. | ||
| 2 Reattach right end of release cable to eyelet at top of telescoping strut (2). | |||
| 3 Position shrink-on tubing (1) over right cable connection to eyelet. | |||
| 4 Reattach left end of release cable to eyelet at top of telescoping strut (2). | |||
| 5 Position a second piece of shrink-on tubing (3), approximately 25 mm long, over left cable connection eyelet. | |||
| 6 Carefully heat tubing until they shrink securely over release cable ends and eyelets of telescoping strut. |
|||
| *WH58.30-Z-1004-20A | |||
| 7 Verify proper function of easy-entry seat. |
Commercially available tools
| Number | Designation |
|---|---|
| WH58.30-Z-1004-20A | Hot-air gun |