Deployment of emergency tensioning retractor units when no deployment device is present - AR91.40-P-0611-05A
| AR91.40-P-0611-05A | Deployment of emergency tensioning retractor units when no deployment device is present | ||
| Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Model 163, 168, 170, 202 as of 1.7.93, 203, 208, 209, 210, 215, 220, 230, 414, 463 | AS91.00-Z-0001-01A | |
| Store airbag units with the discharge opening facing upwards, do not subject to temperatures exceeding 100 °C, interrupt any current supply to the units prior to working on them | |||
| Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Model 202 up to 30.6.93 Store airbag units with discharge opening facing upwards, do not subject to temperatures exceeding 100 °C, interrupt any current supply to the units prior to working on them, and unplug test connector/plug connector from airbag (AB) with emergency tensioning retractor (X11/13) | AS91.00-Z-0001-01B | |
| Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units | With model 163, 168, 170, 202, 203, 209, 208, 210, 215, 220, 230, 414, 463 | AH91.60-P-0611-02P | |
| Ignition cable for firing airbag and seat belt tensioner units | WF58.50-P-9160-02A | ||
| Notes on disposing of airbag and emergency tensioning retractor units | All models | OS91.00-P-0001-01A |
- Fabricate ignition cables at least 10 m long with a pressure switch at the end.
- Plug the 2-pin plug into the corresponding emergency tensioning retractor unit.
- Connect ignition cables to the battery.
- Press both pressure switches simultaneously.
Keep a distance of 10 m for safety.
Application of shop-made ignition cables