Fault code description for purge control valve, ME - AD07.61-P-4000-19L
| Purge control valve, voltage supply | |||
|---|---|---|---|
| 1 | Fault code ( |
P2026 (P0443) | |
| 2 | Fault storage | after expiry of test duration and fault | |
| Actuation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp |
following two successive driving cycles with faults | ||
| 3 | Checking frequency | Continuous | |
| 4 | Checked signal or status | Voltage and current at purge control valve | |
| 5 | Fault setting conditions | Voltage lower than 4 volts | |
| Limit values | Current higher than 4.2 amps | ||
| Short circuit to ground Short circuit to+12 V Open circuit in wiring |
No voltage on the purge control valve, Approx. 4 to 8 V on under no load output of the ME control unit approx. 1 seconds |
||
| Checking duration | |||
| 6 | Actuation of the purge control valve is checked for to detect a line discontinuity and short-circuit (to ground or battery voltage). A short circuit to ground and a line discontinuity will be recognized when the output stages are locked, while a short circuit to the battery voltage is recognized when the output stages are conducting. The output stage is immediately no longer activated when a fault arises. |
||