Electric suction fan, ME-SFI fault code description - AD07.61-P-4000-71L
| Electric suction fan, actuation | |||
|---|---|---|---|
| 1 | Fault code | P2073 (-) | |
| ( |
|||
| 1B | Engine 112, 113 as of 1/01 | P2073-[1 ] Short circuit to positive (-) | |
| Fault code | P2073-[2] Short circuit to ground(-) | ||
| ( |
P2073-[4] Interruption (-) | ||
| 2 | Fault storage | After expiry of test duration and fault | |
| Activation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp |
No activation | ||
| 3 | Checking frequency | Continuous | |
| 4 | Checked signal or status | PWM signal actuation and voltage supply for electric suction fan. | |
| 5 | Fault setting conditions | Fault if the duty cycle is greater than 90 %. | |
| Short circuit to positive | Fault if the duty cycle is lower than 10%. | ||
| Short circuit to ground Interruption | PWM signal actuation missing. Voltage supply (circuit 30) to electric suction fan interrupted. | ||
| 6 | Check prerequisites | Battery voltage between 8 and 17V | |
| 7 | In the event of a fault, the output stage is locked or switched for further troubleshooting. A short circuit to ground and a line interruption will be detected when the output stages are locked, whilst a short-circuit to positive is detected when the output stages are conducting.
Pay attention to the variant coding of the AAC or comfort AAC control and operating units. |
||