ETC control unit, ME-SFI fault code description - AD07.61-P-4000-29L
| 1 | Fault code | P205E Internal fault (variant, memory, transmission) (P0702) |
| ( |
P2067 Selector lever module incorrectly coded (P0705) | |
| P2068 CAN message for rear wheel speeds from ESP control unit missing or incorrect (P0720) | ||
| P20D5 The torque request from the ETC control unit is implausible. Implausible (P0702) | ||
| P20D6 CAN transmission error of torque request from ETC control unit (P0702) | ||
| P20D7 CAN transmission error of torque request from ETC control unit (P0702) | ||
| 2 | Fault storage | After expiry of test duration and fault |
Actuation of the indicator lamp
|
|
|
| 3 | Checking frequency | Continuous |
| 4 | Checked signal or status |
|
| 5 | Faults are detected by the ETC control unit and sent via the CAN data bus to the ME-SFI engine control unit. Fault storage and actuation of the CHECK ENGINE (MIL) indicator lamp is carried out by the ME-SFI control unit. Also read out ETC fault memory. |