LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2000 >> ML430 >> Repair and Diagnosis >> Engine Performance >> Tune-Up >> Mixture Formation - 163 Chassis (3 Of 4) >> Self-Diagnostic System >> EGR [ARF] pressure transducer, ME-SFI fault code description - AD07.61-P-4000-51AA

EGR [ARF] pressure transducer, ME-SFI fault code description - AD07.61-P-4000-51AA

    EGR [ARF] vacuum transducer
1 Fault code
(USA ONLY Display on generic scan tool)
P2027 (P0403)
2 Fault storage After expiry of test duration and fault
Activation of the engine diagnosis indicator lamp (EURO3/4)
or CHECK ENGINE (MIL) malfunction indicator lamp USA ONLY
Following two successive drive cycles with faults
3 Checking frequency Continuous
4 Checked signal or status Current/ voltage test at EGR [ARF] pressure transducer
5 Fault setting conditions  Voltage lower than 2, 5 volts
Limit values   Current higher than 4, 2 amps
  Short circuit to ground No voltage at EGR [ARF] pressure transducer
  Short-circuit to +12 V Approx. 4 to 8 V at output of ME-SFI control unit under no load.
  Open circuit in wiring  
6 Check prerequisites Battery voltage between 8 and 17V
7 IMPORTANT A check is performed for a line interruption and short-circuit (to ground or battery voltage). A short circuit to ground and a line interruption will be detected when the output stages are locked, whilst a short circuit to the battery voltage is detected when the output stages are conducting.
The output stage is immediately no longer activated when a fault arises.