Air conditioning (AC) system, ME-SFI fault code description - AD07.61-P-4000-65L
| Air conditioning | ||
|---|---|---|
| 1 | Fault code | P20CD AC compressor torque implausible (-) |
| ( |
P20CE Refrigerant pressure in air conditioning too high (-) | |
| P20D0 The air conditioning requests an implausible fan output (-). | ||
| 2 | Fault storage | After expiry of test duration and fault |
| Activation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp |
No activation | |
| 3 | Checking frequency | Continuous |
| 4 | Checked signal or status | AC compressor torque, refrigerant pressure, fan target speed signal |
| 5 | Fault setting conditions | Fault present when the calculated maximum value of 765 Nm is requested. |
| AC compressor torque, refrigerant pressure | Fault present when the calculated maximum value of 127 bar is sent. | |
| Fan target speed signal | Fault present when the calculated maximum value of 255 % is requested. | |
| 6 | Check prerequisites |
|