Check condition of battery - AR54.10-P-1129Z
MODEL 129, 163, 168, 170, 202, 208, 210, 414
Modification notes
| 24.2.06 | Cold test current | 12 Ah | *BE54.10-P-1002-01A |
| Checking | |||
|---|---|---|---|
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Visual inspection for external leaks | Remove/install battery |
|
| Model 163.113/128/136/154/157/172/174/175 | AR54.10-P-0005GH | ||
| Model 168 | AR54.10-P-0005GC | ||
| Model 414 | AR54.10-L-0005VA | ||
| Model 129, 170,202,208,210 | AR54.10-P-0005EA | ||
| Dispose of battery | OS54.10-P-0001-01Z | ||
| 2 | Check fluid level in battery, replenish with distilled water if necessary | ||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 3 | Check battery | AR54.10-P-1129-01A | |
| Cold cranking amps as per EN | *BE54.10-P-1002-01A | ||
| *WH58.30-Z-1008-09A | |||
| *WH58.30-Z-1009-09A | |||
| *WH58.30-Z-1010-09A | |||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 4.1 | Reduce increased voltage after charging process | On a battery, that is disconnected from the onboard electrical system and with the message "Surface voltage" in the display of the Midtronics battery tester and analyzer MCR 717 | AR54.10-P-1129-03A |
| *WH58.30-Z-1008-09A | |||
| *WH58.30-Z-1003-09A | |||
| 5.1 | Charge battery | If test code "Charge and test" is displayed on Midtronics battery tester and analyzer MCR 717 |
AR54.10-P-1130Z |
Test and adjustment values for the battery
| Number | Designation | 12 Ah | 30 Ah | 35 Ah | 46 Ah | ||
|---|---|---|---|---|---|---|---|
| BE54.10-P-1002-01A | Cold test current | as per EN | A | 170 | 540 | 520 | 420 |
Test and adjustment values for the battery
| Number | Designation | 60 Ah VRLA | 60 Ah VRLA | 62 Ah | ||
|---|---|---|---|---|---|---|
| BE54.10-P-1002-01A | Cold test current | as per EN | A | 680 | 510 | 480 |
Test and adjustment values for the battery
| Number | Designation | 70 Ah VRLA | 74 Ah | 80 Ah VRLA | 84 Ah | ||
|---|---|---|---|---|---|---|---|
| BE54.10-P-1002-01A | Cold test current | as per EN | A | 760 | 680 | 800 | 700 |
Test and adjustment values for the battery
| Number | Designation | 90 Ah VRLA | 95 Ah VRLA | 100 Ah | ||
|---|---|---|---|---|---|---|
| BE54.10-P-1002-01A | Cold test current | as per EN | A | 950 | 850 | 760 |
Commercially available tools
| Number | Designation |
|---|---|
| WH58.30-Z-1003-09A | Volt ampere tester |
| WH58.30-Z-1008-09A | Battery tester and analyzer |
| WH58.30-Z-1009-09A | Red terminal clamp for battery tester and analyzer |
| WH58.30-Z-1010-09A | Black terminal clamp for battery tester and analyzer |