CL test of electrical system motor actuation relay - AD80.20-P-6001-43GH
| Scope of test | Measuring instrument/Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Central locking locks everything HHT actuation |
All doors closed and unlocked. | All doors and fuel tank flap are locked |
|
|
| 1.1 | Central locking unlocks everything HHT actuation |
All doors closed and locked. | All doors and fuel tank flap are unlocked |
|
|
| 1.2 | Central locking relay, lock all doors (F1k20) Function |
Replace relay (F1k20) by relay (F1k15), Repeat test 1.0 |
All doors and fuel tank flap are locked | If test 1.0 in order:
|
|
| 1.3 | Central locking relay, unlock left door and fuel tank flap (F1k24) Function |
Replace relay (F1k24) by relay (F1k15), close and lock left front door |
Left front door is unlocked | Value in order:
|
|
| 1.4 | Central locking relay, unlock right door and rear doors (F1k23) Function |
Replace relay (F1k23) by (F1k15), repeat test 1.1 | All doors and fuel tank flap are unlocked | If the same fault pattern emerges when test 1.1 is repeated:
|
|
| 1.5 | Central locking relay, unlock tailgate (F1k15) Function |
Replace relay (F1k15) by (F1k23), close and lock tailgate |
Tailgate is unlocked | Value in order:
|