Checking wiring harness - AR54.18-P-0600-01A
During tests on the airbag control unit a corresponding test cable must be used in combination with the
126-pin socket box.
Connect electrical connection kit with test cable.
- Check lines for resistance using a continuity meter as per the wiring diagram, starting at the corresponding control unit.
The resistance must be < 0.5 Ω.
- Perform system test in accordance with diagnosis specifications.