LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2000 >> CL500 >> Repair and Diagnosis >> General Information >> OEM General Information >> Emergency Equipment - 215 & 220 Chassis >> Testing & Repair >> Remove/install extinguishing agent lines on underbody - AR86.10-P-0115MB

Remove/install extinguishing agent lines on underbody - AR86.10-P-0115MB

MODEL 220.1 /8 with CODE (Z04) Light armoring with CODE (Z07) Top protection with fire extinguishing system 

Fig 1: Identifying Extinguishing Agent Lines Remove/Install Components On Underbody - Shown On Model 220.1
G04851566

Shown on model 220.1 

REMOVINGINSTALLING Remove/Install     
1 Ignition Off, detach transmitter key from the electronic ignition switch control unit    
2 Remove fuses no. 54 and no. 58 from rear fuse and relay module IMPORTANT The rear fuse and relay module is located below the right rear seat See ↓  
REFER TO BASIC KNOWLEDGE   Fuse assignment of rear fuse and relay box GF54.15-P-1256-01MB
3 Remove left or right rear wheelhouse    
REFER TO MAINTENANCE Remove/install wheels, rotate if necessary   AP40.10-P-4050Z
4 Remove left rear inner fender or right rear inner fender    
5.1 Disconnect threaded connection (4) on left underbody extinguishing agent line (1) When removing left underbody extinguishing agent line (1).
IMPORTANTInstallation:  Observe tightening instructions.
See ↓
 
    Tightening instructions for fire extinguishing system extinguishing agent lines AR86.10-P-0114-01A 
5.2 Disconnect threaded connection (5) on right underbody extinguishing agent line (2) When removing right underbody extinguishing agent line (2).
IMPORTANTInstallation:  Observe tightening instructions.
See ↓
 
    Tightening instructions for fire extinguishing system extinguishing agent lines AR86.10-P-0114-01A 
6 Disconnect threaded connection on left underbody extinguishing agent line (1) or right underbody extinguishing agent line (2) on corresponding distributor fittings extinguishing agent line (3) IMPORTANTInstallation:  Observe tightening instructions.
See ↓
 
    Tightening instructions for fire extinguishing system extinguishing agent lines AR86.10-P-0114-01A 
7 Remove pipe clamps (6) from left underbody extinguishing agent line (1) or right underbody extinguishing agent line (2) IMPORTANT Mark position of left underbody extinguishing agent line (1) or right underbody extinguishing agent line (2) and pipe clamps (6) to be removed  
    IMPORTANTInstallation:  First position bolts with pipe clamps (6) and then tighten pipe clamps (6) after aligning and screwing left underbody extinguishing agent line (1) or right underbody extinguishing agent line (2)  
    TORQUE SPECIFICATION *BA86.10-P-1001-01B 
8 Remove left underbody extinguishing agent line (1) or right underbody extinguishing agent line (2) IMPORTANT Do not bend left underbody extinguishing agent line (1) or right underbody extinguishing agent line (2)  
9 Install in the reverse order    
10 Perform self-test for fire extinguishing system   AR86.10-P-0101-01MB 
TORQUE SPECIFICATION FIRE EXTINGUISHING SYSTEM

Number Designation Model 220.1/8 with fire extinguishing system
BA86.10-P-1001-01B Nut, pipe clamp for extinguishing agent line to body Nm 10