Retrofitting separation switch - AN54.10-P-0002-03I
| Number | Designation | Model 220 | |
|---|---|---|---|
| BA54.10-P-1003-01C | Adapter on positive battery terminal | Nm | 20 |
- Install positive lead (13) on battery terminal (14).
- Screw on adapter (15).
Adapter on battery positive pole.
- Connect positive lead (13) to 1st battery (G1).
- Fasten separation switch (16) on mount for auxiliary parts (17) with M6 x 20 screws and M6 nuts.
- Install additional battery ground lead (18) and 1st battery ground lead (19) on separation switch (16) contact and screw on with nut.
- Connect ground lead (20) to battery ground point (W10).
- Position ground lead (20) on free contact of separation switch (16) and screw on with nut.
- Connect ground lead (19) for separation switch (16) to 1st battery.
- Install battery frame (1).
- Install mount for additional parts (17) with separation switch (16).
M6 x 12 screws.