Home >> Mercedes Benz >> 2000 >> C230 >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Overall Vehicle -- 202 Chassis >> Miscellaneous Notes >> Releasing gas from gas strut and emptying a Risk of injury from drilling gas-filled subassemblies or components (gas filling noncombustible) - OS00.00-P-1001-01A

Releasing gas from gas strut and emptying a Risk of injury from drilling gas-filled subassemblies or components (gas filling noncombustible) - OS00.00-P-1001-01A

Wear safety glasses and face mask. 

  1. Clamp gas-operated strut in machine vise of pillar drilling machine.

    IMPORTANT Conrod must point away from body, no other persons must be within danger area.

  2. Drill gas-operated strut approx. 20 mm (dimension a) from bottom of gas-operated strut Q with a 3 mm drill (arrow). Drill with as little force as possible.
  3. Unclamp gas-operated strut, pump gas-operated strut empty by pressing conrod in several times.

    IMPORTANT Observe regulations for disposal of hydraulic oil.

  4. Dispose of gas-operated strut (worn part).
    Fig 1: Releasing Gas From Gas Strut