Correcting oil level in air conditioning following repair or slow refrigerant loss - AR83.30-P-5251C
MODEL 129 with CODE (580) Air conditioning or, for USA, Tempmatic with CODE (581a) Air conditioning (automatic)
A/C compressor 10PA17
| Perform work quickly, compressor oil is hydroscopic When evacuating refrigerant add the quantity of compressor oil removed from the refrigerant circuit when recharging the air conditioner. |
|||
| 1 | In the event of refrigerant loss < 400 g (no leakage noted) do not add compressor oil ↓ | ||
| Perform leakage test | |||
| 2 | In the event of refrigerant loss > 400 g (leakage noted) add new compressor oil and also ↓ | *BF83.55-P-1009-01A | |
| replace fluid reservoir | with air conditioning or for USA with Tempmatic Code 580 | ra83001290540x | |
| with air conditioning (automatic) code (581a) | AR83.30-P-6520C | ||
| 3 | Switch on air conditioning and allow engine to idle for approx. 4 minutes | Blower to max. |
|
| 4 | Check air conditioning for proper function | replace evaporator temperature sensor (B10/6) |
| Number | Designation | A/C compressor 10PA17 refrigerant R12 in model 129 | A/C compressor 10PA17 refrigerant R134a in model 129 | ||
|---|---|---|---|---|---|
| BF83.55-P-1009-01A | Additional oil quantity when leakage is noted | Compressor oil | cm3 | 20 | 20 |
| Specifications for service products | Page | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||