Ignition of removed emergency tensioning retractors - AR91.40-P-0611-02A
|
|
Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. |
Except model 202 up to 30.6.93 Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. Interrupt power supply when working on such units |
|
|
|
Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. |
Model 202 up to 30.6.93 Store airbag units with discharge opening facing upwards, do not subject to temperatures exceeding 100 °C, interrupt any current supply to the units prior to working on them, and unplug test connector/plug connector from airbag (AB) with emergency tensioning retractor (X11/13) |
|
|
|
Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units |
||
|
|
Notes on disposing of airbag and emergency tensioning retractor units |
All models |
- Plug the 2-pin plug connector (8) into the unit to be scrapped.
- Dial the rotary switch (4) to position "1".
- Press the battery control pressure switch (2) and deployment pressure switch (3) simultaneously.
Keep a distance of 10 m for safety.
After a successful deployment, the deployment indicator lamp (5) flashes.
Using the deployment device