Wiring Continuity
WARNING: This page is about a different car, the 1995 Mercedes-Benz S500, 1995 Mercedes-Benz S420, and 1995 Mercedes-Benz E420. However, it is still accessible from the selected car via links, so may be relevant.
- Connect voltmeter between generator B+ terminal and ground. Voltmeter should indicate battery voltage. If battery voltage is not indicated, check battery and check wiring between generator and battery for corrosion, loose terminals, etc.
- Turn ignition on and ensure instrument cluster charge indicator light (battery symbol) comes on. If light does not come on, check wiring between generator and warning light, including indicator bulb.