Deployment of airbag units when no deployment device is present - AR91.60-P-0611-05A
| AR91.60-P-0611-05A | Deployment of airbag units when no deployment device is present | ||
| Risk of injury. Injuries may result when performing testing or repair work on airbag or emergency tensioning retractor units. | MODELS 163, 170, 202 as of 1.7.93, 208, 210, 414, 463 Store airbag unit with expulsion area on top, do not subject to temperatures above 100°C. When working on these units, disconnect the power supply. |
AS91.00-Z-0001-01A | |
| Risk of injury. Injuries may result when performing testing or repair work on airbag or emergency tensioning retractor units. | MODEL 202 up to 30.6.93 Store airbag unit with expulsion area on top, do not subject to temperatures above 100°C. When working on these units, disconnect power supply and unplug the SRS test connector (X11/13). |
AS91.00-Z-0001-01B | |
| Notes on controlled deployment of airbag, side airbag and emergency tensioning retractor units | Models 163, 168, 170, 202, 203, 208, 210, 215, 220, 414, 463 | AH91.60-P-0611-02P | |
| Ignition cable for firing airbag and seat belt tensioner units | WF58.50-P-9160-02A | ||
| Notes on disposal of airbags and emergency tensioning retractors | All models | OS91.00-P-0001-01A |
Application of shop-made ignition cables
- Make up ignition cable of min. 10 m length with pressure switch.
- Plug the 2-pin plug connector into the corresponding airbag unit.
- Connect ignition cables to the battery.
- Press both pressure switches simultaneously.
- For airbag units with 2 squibs, both must be deployed. To do this, repeat steps 2 through 4 after plugging the ignition cable into the second squib.
Keep a distance of 10 meters for safety.