Check quiescent current consumption - AR54.10-P-1030C: Notes
MODEL 170
Modification notes
| 5.8.04 | Prerequisites and sequence of quiescent current testing expanded | Steps 2.1, 5.1, 6.1: model 170 with Audio 10 CD radio |
| 1.1 | Prepare test with quiescent current retention unit | AR54.10-P-1030-01AD | |
| Figure | |||
| *WH58.30-Z-1001-09A | |||
| *WH58.30-Z-1012-09A | |||
| 1.2 | Preparing test without quiescent current retention device | AR54.10-P-1030-02AD | |
| Figure | |||
| *WH58.30-Z-1001-09A | |||
| 2.1 | Preparatory measures for the quiescent current check | AR54.10-P-1000-01GH | |
| 3 | Switch off all consumers | Audio 10 RDS radio with CD drawer, code 756), Switch off interior protection, Switch off make-up mirror and Switch off reading lamp, Turn exterior lamp switch to position "0", Close doors, the interior lights must go out automatically after a few seconds, close luggage compartment cover. |
|
| 4 | Check quiescent current | If specification for total quiescent current is not achieved: ↓ | AR54.10-P-1030-03C |
| Determine circuit with increased quiescent current consumption Specification not achieved: ↓ |
AR54.10-P-1030-04C | ||
| Determine fuse-protected components with increased quiescent current consumption Specification not achieved: ↓ |
AR54.10-P-1030-05AB | ||
| Determine non-fuse protected components with increased quiescent current consumption |
AR54.10-P-1030-06AB | ||
| Figure | |||
| Figure | |||
| Figure | |||
| *WH58.30-Z-1001-09A | |||
| 5.1 | Preparatory measures for reference test of quiescent current consumption | AR54.10-P-1000-01GH | |
| 6.1 | Carry out reference test for quiescent current consumption | AR54.10-P-1030-03C | |
| Replace MB Audio 10 RDS radio with CD | AR82.60-P-7502EB |
Commercially available tools
| Number | Designation |
|---|---|
| WH58.30-Z-1001-09A | Multimeter |
| WH58.30-Z-1012-09A | Quiescent current retention unit |