Check quiescent current consumption - AR54.10-P-1030AB: Notes
MODEL 163, 202, 208, 210, 129
Modification notes
| 2.8.04 | Prerequisites and sequence of quiescent current test expanded | Steps 6.1, 9.1, 10.1: model 163 with Audio 10 radio CD |
| 1.1 | Open engine hood and raise to vertical position | Model 163 up to A145272, X708318 | AR88.40-P-1000GH |
| Model 163 as of A145273, X708319 | AR88.40-P-1000GI | ||
| 1.2 | Open right rear door window | Model 210 | |
| 1.3 | Open luggage compartment lid or tailgate | Model 202, 208, 129 | |
| 1.4 | Remove rear seat bench | Model 210 sedan | AR91.12-P-1700F |
| 1.5 | Fold rear seat cushion forward and remove battery compartment cover | Model 210 T-model | |
| 2.1 | Open side windows of front doors | Model 129, 163 | |
| 3.1 | Run engine until warm | Model 129.076, 163 |
|
| 4.1 | Switch off engine and wait 12 minutes | Type 129.076 Model 163 |
|
| 5.1 | Prepare test with quiescent current retention unit | Model 163 | AR54.10-P-1030-01GH |
| Model 202, 208, 129 | AR54.10-P-1030-01AB | ||
| Model 210 | AR54.10-P-1030-01AC | ||
| Figure | |||
| *WH58.30-Z-1001-09A | |||
| *WH58.30-Z-1012-09A | |||
| 5.2 | Preparing test without quiescent current retention device | Model 163 | AR54.10-P-1030-02GH |
| Model 210 | AR54.10-P-1030-02AC | ||
| Model 202, 208, 129 | AR54.10-P-1030-02AB | ||
| Figure | |||
| *WH58.30-Z-1001-09A | |||
| 6.1 | Preparatory measures for the quiescent current check | AR54.10-P-1000-01GH | |
| 7 | Switch off all consumers | Turn exterior lamp switch into position "0", Close doors, the interior lights must go out automatically after a few seconds. |
|
| 8 | Check quiescent current | Model 163,202,208,210 | AR54.10-P-1030-03AB |
| Model 129 | AR54.10-P-1030-03CS | ||
| If specification for total quiescent current is not achieved: ↓ | |||
| Determine circuit with increased quiescent current consumption | |||
| Model 163,202,208,210 | AR54.10-P-1030-04AB | ||
| Model 129 | AR54.10-P-1030-04CS | ||
| Specification not achieved: ↓ | |||
| Determine fuse-protected components with increased quiescent current consumption | AR54.10-P-1030-05AB | ||
| Specification not achieved: ↓ | |||
| Determine non-fuse protected components with increased quiescent current consumption | AR54.10-P-1030-06AB | ||
| Figure | |||
| Figure | |||
| Figure | |||
| *WH58.30-Z-1001-09A | |||
| 9.1 | Preparatory measures for reference test of quiescent current consumption | AR54.10-P-1000-01GH | |
| 10.1 | Carry out reference test of quiescent current consumption | AR54.10-P-1030-03AB | |
| Replace MB Audio 10 RDS radio with CD | AR82.60-P-7502EA |
Commercially available tools
| Number | Designation |
|---|---|
| WH58.30-Z-1001-09A | Multimeter |
| WH58.30-Z-1012-09A | Quiescent current retention unit |