Outside temperature display, location/function - GF54.30-P-4104A

MODEL 129 

MODEL 140 as of 1.6.96 

MODEL 170 

MODEL 163, 202 with CODE (240a) Outside temperature display 

MODEL 202 as of 1.8.96 

MODEL 168 

MODEL 208 up to 31.7.99, 210 as of 1.6.96 up to 30.6.99 

To display the temperature, the outside temperature indicator A1p4  requires:

The outside temperature is determined by the outside temperature indicator temperature sensor B14. The temperature sensor is installed at the front left of the vehicle under the bumper and connected to the instrument cluster A1 via the 21 or 25-pin connector, coding part A terminal 1 and 2.

The speed signal, engine running time and engine temperature are determined internally by the instrument cluster A1.

Since the outside temperature display depends on the speed, engine running time and coolant temperature, high temperatures (influenced by the heat generated by the engine, for example) are not displayed when the vehicle is stationary or moving slowly.

Function, model 202 until 08/95

When the ignition is switched on and off and at speeds below approx. 20 km/h, the last temperature measured is stored and displayed.

If the measured outside temperature drops below the stored value, the current measured temperature is displayed.

If the outside temperature rises above the stored value, the current measured outside temperature is displayed only after the following delays:

Function 

Model 129, model 140 as of 1.6.96, model 170, model 202 as of 08/96, model 163, model 168, model 208 and model 210 

If the measured outside temperature drops below the stored value, the current measured temperature is displayed.