Treatment of battery when the car is laid up - ra54001400006x(0006)
Model 140
Preliminary work:
Charge battery, check state of charge and capacity, A (Charging, checking the state and capacity of the battery ).
Operation no. of operation texts and work units or standard texts and flat rates:
Observe warning information and safety regulations (Initial filling of the battery
, A).
Retract trunk lid handle by actuating switch on trunk lock.
The pin in the trunk lid auxiliary lock should not be extended, if necessary repeat locking procedure.
- Disconnect ground cable from battery.
- Recharge battery every three months and then measure electrolyte density.
Electrolyte density specification 1.28 kg/dm3 (see table).
Never allow the battery to stand discharged, otherwise sulfate will deposit on the plates. Sulfated plates damage the battery leading to premature failure.
Anti-freeze protection as function of state of charge
| State of charge in kg/dm3 at 20 °C | Electrolyte density | Normal solidification temperature of electrolyte in °C |
|---|---|---|
| charged | 1.28 | - 65 |
| semi-charged | 1.20 | - 30 |
| discharged | 1.12 | - 4 |
Examples:
Electrolyte density at 20 °C 1.28 kg/dm3
Electrolyte density at 35 °C 1.29 kg/dm3
Electrolyte density at 5 °C 1.27 kg/dm3
| Acidimeter | e. g. Hazet |