Removing and installing combination relay - ra540b1401500x(1500)
B. Removal, installation Model 140 as of 09/95
Operation no. of operation texts and work units or standard texts and flat rates:
B. Removal, installation (as of 09/95)
| Quiescent current retention unit | disconnect, connect. |
| Ground cable on battery | disconnect, connect. |
| Fuse box cover (1) | remove, install. |
| Connector | remove from mount, install. |
| Connector mount | remove, install. |
| Screws (3) | unscrew, screw in. |
| Relay box cover (4) | remove, install. |
| Combination relay (N10, N10/2) | remove, install. |
|
NOTE:
The combination relay (N10, N10/2) is arrested with four catch lugs.
|
|
| Electrical connections (arrows) | disconnect, connect. |
COMMERCIALLY AVAILABLE TESTER
| Quiescent current retention unit | e.g. Hans Zeheter CMP 12.2 |