Disconnection and connection of the battery - ra54001400003x(0003)
Model 140
Operation no. of operation texts and work units or standard texts and flat rates:
Observe warning information and safety regulations (Initial filling of the battery
, A).
NOTE:
Perform work precisely in sequence specified to avoid danger of short circuit.
DISCONNECTING
| Quiescent current retention unit | connect if possible. |
| Ground lead on battery | disconnect and remove pole terminal. |
| Shield on positive terminal | swing open. |
| Positive lead | disconnect from battery and remove battery terminal. |
CONNECTING
| Positive battery terminal | connect to battery. |
| Shield on positive terminal | swing shut. |
| Ground pole terminal on battery | connect. |
| If connected | disconnect quiescent current retention unit. |
|
NOTE:
If quiescent current retention unit was connected, skip last step!
|
|
| After connecting the battery perform the following work | set clock in instrument cluster. Code radio (82-7502). Where applicable code automatic pilot system (APS) and load language (82-7502) Synchronize power windows (FUNCTION OF CONVENIENCE CONTROL (POWER WINDOWS AND TILTING/SLIDING ROOF)
). Set timer for stationary heater, where applicable. On vehicles with ADS reactivate steering angle sensor (32-0600) . |
COMMERCIALLY AVAILABLE TESTER
| Quiescent current retention unit | e.g. Hans Zeheter CMP 12.2 |