Removing and installing transmitter/receiver unit - AR82.70-P-8911DA
MODEL 208.3 as of 1.7.00 with CODE (853) MB standard cellular telephone
Shown on model 202
| Removal, installation | |||
| 1 | Connect quiescent current retention unit | *WH58.30-Z-1012-09A | |
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury from caustic burns to eyes and skin from battery electrolyte or from handling damaged lead acid batteries. | No fire, sparks, naked flames or smoking. Wear acid-protective gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 2 | Disconnect ground cable of battery | AR54.10-P-0003A | |
| Notes on battery | All models. | AH54.10-P-0001-01A | |
| 3 | Remove floor paneling in trunk | ||
| 4 | Remove cover above control module plate | ||
| 5 | Unscrew nuts (1) | ||
| 6 | Lift off telephone transmitter/receiver (A35/13) | ||
| 7 | Release connectors on telephone transmitter/ receiver (A35/13) and disconnect | ||
| 8 | Remove telephone transmitter/receiver (A35/13) | ||
| 9 | Install in the reverse order |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation |
|---|---|
| WH58.30-Z-1012-09A | Quiescent current retention unit |