Removing and installing voice control system control module - AR82.70-P-0003AB
MODEL 208.3 as of 1.7.00 with CODE (854) MB portable cellular telephone
| Removal, installation | |||
| 1 | Connect quiescent current retention unit | *WH58.30-Z-1012-09A | |
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury from caustic burns to eyes and skin from battery electrolyte or from handling damaged lead acid batteries. | No fire, sparks, naked flames or smoking. Wear acid-protective gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 2 | Disconnect ground cable of battery | AR54.10-P-0003A | |
| Notes on battery | All models | AH54.10-P-0001-01A | |
| 3 | Remove side cover on left side of trunk | ||
| 4 | Unscrew nut (3) | ||
| 5 | Carefully remove bracket (1) with control modules | ||
| 6 | Unlock connector on voice control system control module (A35/11) and disconnect | ||
| 7 | Loosen sheet metal screws (2) | ||
| 8 | Remove voice control system control module (A35/11) | ||
| 9 | Install in the reverse order |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation |
|---|---|
| WH58.30-Z-1012-09A | Quiescent current retention unit |