Remove/install operating/display unit with control module - AR82.85-P-7472K
MODEL 208 with CODE (352a) COMAND operating, display and control module
| Remove/install | |||
| 1 | Connect quiescent current retention unit | AR54.10-P-1030-07I | |
| *WH58.30-Z-1012-09A | |||
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury from caustic burns to eyes and skin from battery electrolyte or from handling damaged lead acid batteries. | No fire, sparks, naked flames or smoking. Wear acid-protective gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 2 | Disconnect ground cable of battery | AR54.10-P-0003A | |
| Notes on battery | All models | AH54.10-P-0001-01A | |
| 3 | Insert removal tool (1) into the recess clearance | ||
| *WH58.30-Z-1008-19A | |||
| 4 | Remove COMAND operating, display display and control module (A40/3) | ||
| 5 | Disconnect couplings | ||
| 6 | Disconnect fiber optic cable connector (D2B) | ||
| Covering fiber optic cable | AR82.95-P-0005-01A | ||
| Notes on fiber optic cable | Models 129, 168, 170, 202, 203, 208, 210, 215, 220, 463. | AH82.70-P-0001-02A | |
| 7 | Unlatch removal tool (1) | ||
| 8 | Install in the reverse order | ||
| 9 | Read diagnostic trouble code memory and erase | Stored faults which can result from cables being disconnected or from simulation during removal and installation or test work, have to be processed and erased in the fault memories after completing the work. Refer to: ↓ STAR DIAGNOSIS. |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation | |
|---|---|---|
| WH58.30-Z-1012-09A | Quiescent current retention unit | |
| WH58.30-Z-1008-19A | Removal tool | 000 833 0561 |