Withdrawing instrument cluster - AR54.30-P-6015-01Z

Fig 1: Identifying Extractor Hooks (140 589 02 33 00)
G04715754

NOTES Do not damage instrument panel when pulling out

Carefully insert extractor hooks about 8 cm with the curved end facing down at the side between instrument cluster panel and turn through 90° inwards toward instrument cluster.

Fig 2: Inserting Extractor Hooks Between Instrument Cluster Panel
G04715755

Carefully pull out extractor hooks until they engage in the extractor ribs of the instrument cluster (A1)

Fig 3: Identifying Extractor Hooks Engaged In The Extractor Ribs Of The Instrument Cluster
G04715756

Pull out instrument cluster about 5 mm with the left-hand and right-hand hook alternately.

IMPORTANT When pulling, press the extractor hooks outwards at an angle of about 120° in order to prevent them slipping off. Never pull on both extractor hooks at the same time.

Fig 4: Pressing The Extractor Hooks Outwards At An Angle
G04715757